Electric built-in socket (A10)

The socket is freely accessible on the case of the vacuum cleaner and it is intended for

feeding (e.g.

electric rotation nozzle, beat nozzle or similar appliances MAX. input

70 W). Plug in the end piece to the socket (Fig. 9). After switching on the vacuum cleaner,

the nozzle function is started automatically.

CAUTION

– The floor nozzle with the rotation brush is not intended for vacuuming impurities from

carpets with high pile.

– If the brushes with bristles are blocked during operation (e.g. due to sucking in large

foreign objects, due to winding carpet piles, thread or hair on them etc.) turn off

the vacuum cleaner by switch

A3. Then remove the cause of blocking or clean the

brushes with bristles if necessary (see par. IV. MAINTENANCE).

!

Dust filter replacement

If you find out that the suction performance of the vacuum cleaner is reduced, make sure

that the dust paper dust bag is not full and if necessary, empty it. Put the bottom part of

the vacuum cleaner on a flat base, hold the lid in the cavity and re

move it by pulling

(Fig. 10). Hold the dust filter at its head, remove it from the throat by tilting and remove it

from the suction space of the vacuum cleaner by pulling it upwards (Fig. 11). Insert a new

dust filter to the suction space of the vacuum cleaner so that the edge with the cavity in

the head of the filter snaps behind the two cogs (Fig. 12) and then push the head of the

filter to slide the throat into the dust filter. Slide the cog on the lid to the hole in the case

of the vacuum cleaner and then snap the lid in.

Replacing micro-filters

After replacing about 5 dust filters, micro-filters must be replaced with new ones. Dispose

of a used dust paper filter together with micro-filters with common municipal waste.

Suction micro-filter

Remove the micro-filter in the dust filter space (Fig. 13) and replace it with a new one.

Insert a micro-filter in the suction space in the opposite way; its proper position is given

by two cuts.

Exhaust micro-filter

Replace by pushing the cap in the upper part of the grating and remove it from the

vacuum cleaner by tilting (Fig. 14). Take out the micro-filter and replace it with a new one

(Fig. 15). Keep the direction of inserting micro-filters (the dark part is directed towards the

grating). Slide the cog on the grating to the hole in the case of the vacuum cleaner and

then snap the grating in.

CAUTION

Do not switch the vacuum cleaner on and off by unplugging the power cord from

a socket. If the knob is in “

min” or “max“ position and the vacuum cleaner is leaning

(e.g. against furniture, wall), the vacuum cleaner can fall and it can be damaged due to

the aggregate (motor) moment.

!