Fieldpiece SVG3 - Digital Micron Vacuum Gauge User Manual

Fieldpiece, Easy view vacuum gauge, Quick start

Advertising
background image

01

03

06

02

05

04

07

09

12

08

11

10

Directly to

Service Port

Schrader Core

Removal Tool

Hose

To

Pump

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

Quick Start

1. Power on your SVG3 by holding the

button for 1 second.

2. Connect to system directly to an

unused service port, a Schrader core

removal tool (SCRT), or via hoses.

3. View vacuum in microns of mercury

on the top line and rate of change

(±microns per minute) on the bot-

tom line.

Certifications

C-Tick (N22675)

CE

WEEE

RoHS Compliant

Description

Proper evacuation of any system

exposed to atmosphere is critical to

ensure efficient operation and the

SVG3 is the right tool to help HVACR

professionals verify they reach proper

vacuum levels. See your vacuum

measurement clearly and easily with

the newly designed easy-view hook

and backlight. SVG3 is built for field

use with its ruggedized rubber case.

Reducing connections mini-

mizes leaks, so the SVG3 has

a female 1/4" flare fitting with

schrader depressor so you can

connect it directly to a service port or

your valve core removal tool.

Be alerted when you've reached

your desired vacuum levels with built

in Hi and Lo Alarm functions. Check for

leaks with rate indication in microns

per minute. The HVACR professional

can do more with confidence that he

is doing the job right the first time.

Display

Top Line: Live Vacuum Measurement

in Microns of Mercury (Hg)

Bottom Line: Rate of Micron Change

or Alarm Stopwatch

Auto Power Off Enabled

Battery Life

Alarm Set Mode

Low Alarm Mode

High Alarm Mode

Rate of Micron Change

(±Microns Per Minute)

Fieldpiece

Easy View

Vacuum Gauge

OPERATOR'S MANUAL

Model SVG3

Controls

Hold 1 second to power SVG3 on/ off. Press

<1 second to toggle backlight.

Press to activate Alarm Lo, Alarm Hi, and

return to real time mode. Hold 1 second to

enter or exit Alarm Set mode.

Lock in selected digit and move to next in

Alarm Set Mode.

Increase or decrease blinking digit in

Alarm Set Mode. Toggle to display

stopwatch or rate of change when an

alarm is activated in real time mode.

BACKLIGHT NOTE: The backlight timer is automatically

extended for 1 min when any button is pressed. A short

press of toggles backlight on and off.

Specifications

General

Operating temperature: 32°F (0°C) to 122°F (50°C) at

<75%RH

Storage temperature: -4°F to 140°F (-20°C to 60°C), 0

to 80% RH (with battery removed)

Temperature coefficient: 0.1 x (specified accuracy)/°C

(<18°C or >28°C)

Over range: "OL" is displayed

Power: 4 x AAA batteries, NEDA 24A, JIS UM4, IEC R03

Auto power off: after 15 minutes of readings more

than 10,000 microns if APO is active.

Battery life: 40 hours standard use (alkaline) without

backlight use.

Low battery indication:

is displayed when the

battery voltage drops below the operating level.

Vacuum Pressure

Units of measure: microns (µm) of mercury

Connector type: Standard 1/4" female flare fitting. "T"

fitting included ( 3 male flare ports)

Range: 0 to 9999 microns of mercury

Accuracy: ±(5% of reading + 5 microns), 50 to 1000

microns

Resolution: 1 micron (50 to 2000 microns), 250

microns (2001 to 5000 microns), 500 microns (5001

to 8000 microns), 1000 microns (8001 to 9999

microns)

Rate: Microns per minute

Refresh rate: 0.5 seconds

Atmospheric pressure: "OL" will be displayed

Maximum overload pressure: 500 psig

How to Use

Normal Mode

M e a s u re d e e p v a c u u m s t o

monitor your system evacua-

tions. Deep vacuums help remove

non-condensable gases that can

cause problems in a system.

There are many ways to connect to

the system, Fieldpiece recommends

using a SCRT and the shortest vacuum

rated hoses possible. Fewer connec-

tions reduce the potential for leaks.

1. Connect to system. Techs typically prefer connect-

ing to the Schrader Core Removal Tool (SCRT) or an

unused service port.

2. Hold for 1 second to power ON the SVG3.

3. The top display shows the vacuum in microns of

mercury.

4. The bottom display shows how fast the measure-

ment is increasing or decreasing (± microns of

mercury per minute).

Low and High Alarms

Be alerted when you've reached your

desired vacuum levels. Work on other
tasks at the jobsite and let SVG3 alert
you when the system is ready.

Activate the low alarm (default 500

microns) to alert when the vacuum has
dropped to your desired micron level.

Activate the high alarm (default 1000

microns) to see how long it takes the
system to stabilize after the vacuum
pump has been isolated. If the system
does not stabilize over time, you may
have a leak in the system or your con-
nections.

The stopwatch will start when an

alarm is activated. It will restart when
the low alarm has been reached to show
how long you've pulled a vacuum after
reaching your desired micron level. The
stopwatch will stop when the high alarm
has been reached to show how long it
took to rise to your high alarm value.

When an alarm is activated the UP or

DOWN ARROW toggles the stopwatch
and rate of change (± microns per min-
ute) display.

How to Activate the Alarms

1. Press ALARM to activate low alarm.

2. Press ALARM again to deactivate low alarm and

activate high alarm.

3. Press ALARM again to deactivate high alarm and

return to real time mode.

How to Set the Alarms

The default low (500 microns) and

high (1000 microns) alarm values can

easily be set to whatever you want.

1. Hold ALARM for 1 second to enter Alarm Set Mode.

The first digit of LO alarm will blink.

2. Use ARROWS to change the blinking number. Press

ENTER to lock in a digit and move to the next digit.

Repeat for all LO alarm digits.

3. When LO alarm is complete, the first digit of HI alarm

will blink. Use ARROWS to change the blinking

number. Press ENTER to lock in a digit and move to

the next digit. Repeat for all HI alarm digits.

4. When all digits of HI alarm are locked in you will

automatically exit Alarm Set Mode and your

customized alarm values will be saved.

Note: Anytime while in Alarm Set Mode, you can press

ALARM to toggle between alarm HI set and alarm

LO set. Hold ALARM to exit Alarm Set Mode and

save at any time.

Note: "Err" will show if you try to set the HI alarm

lower than the LO alarm, or the LO alarm higher
than the HI alarm.

Vacuum Tips

Follow all manufacturer's evacu-

ation procedures over those in this

manual in regards to specifications on

how to evacuate systems. To achieve

a deep vacuum efficiently Fieldpiece

recommends the following practices.

1. Remove Schrader cores and core depressors from

the service ports using a valve core removal tool

(purchased separately).

2. Use the shortest vacuum rated hoses with the

largest diameter available.

3. Inspect rubber seals at both ends of your hoses for

damage that may result in leakage.

4. Avoid using hoses with low loss fittings when

evacuating a system.

5. Avoid over-tightening the female flare fitting of

the SVG3. Over-tightening may cause the rubber

gasket to wear more quickly and create leaks. It is

not necessary to over tighten SVG3 to the extreme

to create a good seal.

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

(tool not included)

Recommended

Setup

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

To

Pump

To

Service

Port

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

Hose to

Removal

Tool

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

MICRONS OF MERCURY

SVG3

VACUUM

GAUGE

MIN

ALARM

ENTER

Other Common

Setups

Advertising