Installation requirements (cont.) – Fire Magic 3280 Series Sideburner User Manual

Page 8

Advertising
background image

This is a drop-in type unit designed to fi t into countertop enclosures.

Note: This unit should be installed so that it can be removed at a later date if factory service is required.

Any protrusion into the barbecue enclosure higher than 6" below the countertop may obstruct the

frame and prevent the unit from dropping into place.

EXHAUST REMOVAL

If installed or used under a patio roof, the cooking grid area must be fully covered by an exhaust hood with a vent.
An exhaust fan with a rating of 1,000 CFM (cubic feet per minute) or more may be necessary to effectively remove
smoke and other cooking by-products from the area under the hood. Fire Magic Vent Hoods are available to
meet this requirement
. This unit must not be used under unprotected overhead combustible construction. THIS
UNIT MUST NOT BE LOCATED IN A FULLY ENCLOSED AREA OF ANY KIND.

GAS-SUPPLY PLUMBING REQUIREMENTS

For natural gas or a household propane system, rigid

1

/

2

" or

3

/

4

" black steel pipe or local code-approved pipe is

required to conduct the gas supply to the unit. Contact your local gas supplier. Connect this pipe to a required
C.S.A.-approved stainless-steel fl ex connector. DO NOT use a rubber hose within the grill enclosure. Apply
only joint compounds that are resistant to all gasses to all male pipe fi ttings except fl are fi ttings. Make sure to
tighten every joint securely.

A REGULATOR MUST BE PROVIDED AT THE TANK OR GAS SOURCE FOR USE WITH PROPANE.

Note: If

1

/

2

" pipe is used with natural gas, it should be no longer than 20'.

Important:

An external valve (with a removable key) in the gas line is necessary for safety when the unit
is not in use. It also provides for convenient maintenance.

GAS SUPPLY AND MANIFOLD PRESSURES:

For natural gas - normal 7" (17.78 cm) water column (w.c.), minimum 5" (12.7 cm), maximum 10

1

/

2

" (26.7 cm).

For propane gas - normal 11" w.c., minimum 8" (20.3 cm), maximum 13" (33 cm).

INSTALLATION REQUIREMENTS (cont.)

8

L-C2-025

REV 6 - 1407161320

Advertising