SETTING OF PACKING


Follow the instructions:
a) Assemble of the packing in S.
b) Stagger by about 90° between two rings.
c) Place the rings one at a time.

After setting the last packing ring, secure the
packing with the gland and tighten the nut by hand.

After tightening, the shaft should turn by hand as
easily as before the setting of the packing.

Dimensions in mm (in.)

D

D1

A x A

Nb x lgth

Bearing

34

(1.34)

50

(1.97)

8

(0.31)

3 x 130

(3 x 5.12)

24

(0.94)

44

(1.73)

64

(2.52)

10

(0.39)

4 x 170

(4 x 6.69)

32

(1.26)

56

(2.20)

76

(2.99)

10

(0.39)

4 x 207

(4 x 8.15)

42

(1.65)


For the bearing of 24: Do not forget to mount the
[4131] follower between the last packing and the
gland flange.

6.2.6 Internal coating
If the pump has an internal coating, this coating
must be inspected periodically. Any wear or cracks
of the coating found must be immediately repaired.

Failure to do this may lead to accelerated wear of
the coating during operation and corrosion of the
exposed base metal, depending on the material and
pumped liquid. Special attention must be paid to the
coating edges.

Any loss of coating material is considered to be
normal wear and tear on the pump and is not
considered as warranty. Flowserve has applied the
coatings according to the supplier's instructions but
will not be held responsible for coating wear or
cracks that may develop over time.

6.3 Spare parts


6.3.1 Ordering of spares
Flowserve keeps records of all pumps that have
been supplied. When ordering spares the following
information should be quoted:

1) Pump serial number
2) Pump size
3) Part name
4) Part number
5) Number of parts required


The pump size and serial number are shown on the
pump nameplate.

To ensure continued satisfactory operation,
replacement parts to the original design specification
should be obtained from Flowserve.

Any change to the original design specification
(modification or use of a non-standard part) will
invalidate the pump’s safety certification.

6.3.2 Storage of spares
Spares should be stored in a clean dry area away
from vibration. Inspection and re-treatment of
metallic surfaces (if necessary) with preservative is
recommended at 6 monthly intervals.

6.4 Recommended spares and
consumable items


[1500], [2250], [3011], [4130] (or [4200]), [4590-01],
[4590-02], [4590-03]

a) Destroy all the gaskets after dismantling, replace

them when reassembling.

b)

It is recommended that bearings

are not reused after any removal from the shaft.

c) After serving during two years, replace the gland

packing.