the preferred flow region the actual vibration
experienced may be multiplied by up to two.
These standard values can vary with the rotational
speed and the power absorbed by the pump. For any
special case, contact your nearest Flowserve office.

Measuring vibration at regular intervals will show any
deterioration in pump or system operating conditions.

Vibration velocity –

unfiltered

Horizontal pumps
mm/s (in./s) r.m.s.

Normal N

5.6 (0.22)

Alarm N x 1.25

7.1 (0.28)

Shutdown trip N x 2.0

11.2 (0.44)


5.7.6

Stop/start frequency

Pump sets are normally suitable for the number of
equally spaced stop/starts per hour shown in the
table below. Check actual capability of the driver and
control/starting system before commissioning.

Motor rating kW (hp)

Maximum stop/starts per hour

Up to 15 (20)

15

Between 15 (20) and 90 (120)

10

Above 90 (120)

6

Where duty and standby pumps are installed it is
recommended that they are run alternately every week.

5.8 Stopping and shutdown

a)

Close the outlet valve, but ensure

that the pump runs in this condition for no more
than a few seconds.

b) Stop the pump.
c) Switch off flushing and/or cooling/heating liquid

supplies at a time appropriate to the process.

d)

For prolonged shut-downs and

especially when ambient temperatures are likely
to drop below freezing point, the pump and any
cooling and flushing arrangements must be
drained or otherwise protected.

5.9 Hydraulic, mechanical and electrical

duty

This product has been supplied to meet the
performance specifications of your purchase order,
however it is understood that during the life of the
product these may change. The following notes may
help the user decide how to evaluate the implications
of any change. If in doubt contact your nearest
Flowserve office.

5.9.1

Specific gravity (SG)

Pump capacity and total head in meters (ft.) do not
change with SG, however pressure displayed on a
pressure gauge is directly proportional to SG. Power
absorbed is also directly proportional to SG. It is
therefore important to check that any change in SG
will not overload the pump driver or over-pressurize
the pump.

5.9.2

Viscosity

For a given flow rate the total head reduces with
increased viscosity and increases with reduced
viscosity. Also for a given flow rate the power
absorbed increases with increased viscosity, and
reduces with reduced viscosity. It is important that
checks are made with your nearest Flowserve office if
changes in viscosity are planned.

5.9.3

Pump speed

Changing pump speed effects flow, total head, power
absorbed, NPSH

R

, noise and vibration. Flow varies in

direct proportion to pump speed, head varies as speed
ratio squared and power varies as speed ratio cubed.
The new duty, however, will also be dependent on the
system curve. If increasing the speed, it is important
therefore to ensure the maximum pump working
pressure is not exceeded, the driver is not overloaded,
NPSH

A

> NPSH

R

, and that noise and vibration are

within local requirements and regulations.

5.9.4

Net positive suction head (NPSH

A

)

NPSH available (NPSH

A

) is a measure of the head

available in the pumped liquid, above its vapor
pressure, at the pump suction branch.

NPSH required (NPSH

R

) is a measure of the head

required in the pumped liquid, above its vapor pressure,
to prevent the pump from cavitating. It is important that
NPSH

A

> NPSH

R

. The margin between NPSH

A

>

NPSH

R

should be as large as possible.


If any change in NPSH

A

is proposed, ensure these

margins are not significantly eroded. Refer to the
pump performance curve to determine exact
requirements particularly if flow has changed. If in
doubt please consult your nearest Flowserve office
for advice and details of the minimum allowable
margin for your application.

5.9.5

Pumped flow

Flow must not fall outside the minimum and
maximum continuous safe flow shown on the pump
performance curve and or data sheet.