6 fastener torques, 7 setting impeller clearance – Flowserve CPXM User Manual

Page 19

Advertising
background image

CPXM and CPXRM USER INSTRUCTIONS ENGLISH 71569101 10-08

Page 19 of 32

flowserve.com

6.6 Fastener torques

Screw position

Screw size

Torque Nm (lbf·ft)

Casing and

seal cover

M8

M10
M12
M16
M20

16 (12)
25 (18)
35 (26)
80 (59)

130 (96)

Muff coupling

M8

M10

30 (22)
58 (43)

Cartridge seal sleeve

(where applicable)

M5
M8

5.5 (7) *

16 (22) *

* Where a torque wrench is unavailable, slightly tighten the
setscrews to centralize the cartridge seal, then tighten with a T-bar
until a torsional twist between 60 and 90 degrees is achieved. The
torque applied will be approximate to that recommended.

Non-metalic gaskets incur creep

relaxation - before commissioning the pump check
and retighten fasteners to tightening torques stated.

6.7 Setting impeller clearance

This procedure may be required after the pump has
been dismantled or a different clearance is required.

Before carrying out this procedure ensure that the
mechanical seal(s) fitted can tolerate a change in
their axial setting, otherwise it will be necessary to
dismantle the unit and reset the seal axial position
after adjusting the impeller clearance.

If a cartridge seal is fitted loosen it from the shaft.

6.7.1 Setting CPXM impeller clearance
a) Disconnect the muff coupling and clean up the

bores.

b) Clean motor shaft and stubshaft and deburr

where necessary.

c) Replace muff coupling, ensuring that the

grubscrew locates in the stubshaft.

d) The motor end coupling bolts should be slacker

than the pump end coupling bolts so that the
coupling and stubshaft can be rotated relative to
the motor shaft.

e) The motor shaft should be prevented from

rotating by using a C-spanner located in the
keyway (where possible) or by locking the fan
end of the motor.

f) Rotate the coupling until the impeller contacts the

pump casing. This is the zero clearance position
or datum for setting the front clearance.

g) Mark the bracket with a pen and, whilst preventing

the motor shaft rotating, turn the coupling in the
opposite direction by the recommended number of
notches as indicated in the table. For the
remaining steps, take care not to rotate the pump
shaft relative to the motor shaft.

Clearance settings:

Motor frame size

Impeller

diameter

80

90

100 112 132 160 180 200

Clearance

(mm)

0.3 0.3

0.3 0.3 0.3 0.3 0.3 0.3

Up to

210 mm

Notches

7

7

7

7

7

8

8

8

Clearance

(mm)

0.4 0.4

0.4 0.4 0.4 0.4 0.4 0.4

211 to

315 mm

Notches

8

8

8

8

8

9

9

9

h) Carefully loosen and back off the grubscrew and

tighten the coupling bolts, ensuring that the gap
is equal between the coupling halves.

i)

Torque the screws to the specified values:

M 8 - 30 Nm (22 lbf•ft)
M 10 - 58 Nm (43 lbf•ft)

j)

Check that the shaft can turn freely without binding.

k) If a cartridge seal is fitted it should be reset at this

point.


6.7.2 Setting CPXRM impeller clearance
The impeller does not have a fine front clearance
setting and adjustment of the impeller is not normally
required.
a) Disconnect the muff coupling and clean up the

bores.

b) Clean motor shaft and stubshaft and deburr

where necessary.

c) Replace muff coupling, ensuring that the

grubscrew locates in the stubshaft.

d) The motor end coupling bolts should be slacker

than the pump end coupling bolts so that the
coupling and stubshaft can be rotated relative to
the motor shaft.

e) The motor shaft should be prevented from rotating

by using a C-spanner located in the keyway (where
possible) or by locking the fan end of the motor.

f)

With the casing removed, rotate the coupling until
the back clearance is 1.5 to 2 mm (0.06 to 0.08 in.)
as illustrated. This is the setting position and, for
the remaining steps, take care not to rotate the
pump shaft relative to the motor shaft.

Advertising