3 Pipe Taps

3.1 The 1/4 inch pipe taps are dead-ended between the lips. One goes between the first

and second lips and the other goes between the second and third lips. Most users

plug these ports.

These ports should be used if the product pumped polymerizes when sheared or

polymerizes when it contacts the air. In those instances a suitable solvent can be put

into the ports.

Caution: Very light solvents, as thin or thinner than water, may decrease the seal life.
For special problems encountered during installation, contact your nearest Flowserve Sales

and Service Representative or Authorized Distributor.

LS-300

2.3 Position the cartridge gland against the seal chamber face and tighten

the gland stud nuts up evenly, cross staggering the adjustment of the nuts. Do not

over tighten the gland nuts.

2.4 Adjust the bearings, coupling, and impeller so that the shaft is in its operating

axial position. Any subsequent axial adjustment of the shaft requires resetting of

the seal.

2.5 Tighten the set screws in the seal cartridge collar to the shaft.
Suggested minimum torque values for the set screws are as follows:

Alloy C-276 or 316 SS

Torque Value

#10 - 24 UNC

2.3 N-m (20 inch-lbs)

1/4" - 20 UNC

5.0 N-m (45 inch-lbs)

5/16" - 18 UNC

9.0 N-m (80 inch-lbs)

Alloy Steel, Plated

Torque Value

#10 - 24 UNC

3.5 N-m (30 inch-lbs)

1/4" - 20 UNC

9.0 N-m (80 inch-lbs)

5/16" - 18 UNC

118.0 N-m (60 inch-lbs)

2.6 Remove the setting devices from the cartridge sleeve collar. These setting devices

should be saved and reinstalled for seal removal and repair or for repositioning the

pumps impeller.

Eccentric washers or rectangular style setting devices can be repositioned clear of

moving parts and locked in place on the gland for storage. These should be returned

to the setting position for seal removal and repair or for repositioning the pump impeller.