6.7 Select O-ring [13] and stretch slightly. Lightly lubricate with silicone grease.

Install O-ring [13] into the gland assembly [11]. See Figure 10.

6.8 For sizes 2.750 inch (70 mm) install the

vibration dampener [183.1] onto the gland

surface where the stationary face [14] will be

Figure 10

Figure 12

Figure 13

installed. See Figure 11.

For sizes > 2.750 inch (70 mm)

install the

long end of the ed drive pin [5] into the hole

in the gland where the stationary face [14]

will be located. Cut a 0.25 inch (6 mm) slot

in the vibration dampener [183]. See Figure

11. Install onto the gland surface where the

stationary face will be installed with the slot

positioned around the drive pin.

6.9 Select stationary face [14] and lightly lubricate

the O-ring surface using silicone grease.

Install the stationary face [14] into the gland/

vibration dampener assembly [183.1 and 11].

Use hand pressure only. See Figure 12.

For sizes

2.750 inch (70 mm) ensure that

the flats on the stationary face [14] and the

flats on the gland assembly [11] are aligned.

For sizes > 2.750 inch (70mm)

ensure that

the slot on the stationary face [14] and the

square-headed pin [5] are aligned.

6.10 Check for proper seating of the stationary

face by measuring from the back of
the gland assembly to the face of the
stationary face with a caliper or depth
gage. Measure in 3 equally spaced
locations, measurement variations should
not exceed 0.005 inch (0.127 mm).

6.11 Clean the sealing face of the stationary face

[14] to remove any dirt, dust, finger prints,

grease or any other residue using ethyl

alcohol on a clean cloth or tissue.

6.12 Install the gland [11] onto the sleeve

assembly [1]. See Figure 13.

Figure 11

6.13 Thread set screws and quarter-dog set screws

in proper, equally spaced locations in drive collar [58].

Note:

Some sizes > 2.750 inch (70 mm) do not utilize quarter-dog set

screws.