2seal installation – Flowserve High Temperature Metal Bellows Seals User Manual

Page 3

Advertising
background image

3

Seal Chamber Requirements

Figure 1

2

Seal Installation

Cartridge high temperature bellows seals are packaged in a manner to protect

the flexible graphite gaskets during shipping. Carefully unpack the cartridge seal

and separate the gaskets. Flexible graphite gaskets are very fragile; handle

with care.
2.1 Some mechanical seals are sensitive to rotation direction. Verify that the

directional rotation of the shaft corresponds to that of the mechanical seal

before installation. Seals for between-bearing shaft pumps may use

different designs for each end of the pump; check the seal assembly

drawings carefully.

2.2 Remove the axial drive collar screws and drive collar, if installed.
2.3 Place seal gland gasket into its groove. Small dots of grease may be

applied in the seal gland gasket groove in 4 to 6 places to hold the gasket

in position. Care must be taken not to get grease on the seal faces.

2.4 If the sleeve includes a sacrificial O-ring, lightly lubricate it to facilitate

sliding along the shaft. Use a lubricant appropriate for the application.

2.5 For overhung shaft pumps:

2.5.1 Slide the drive collar onto the shaft with the gasket side of the

collar facing the seal chamber. Note: the gasket is installed

separately, in the next step. If the collar assembly includes a key

drive, pin and/or lock ring, install these items. Again, refer to the

assembly drawing.

2.5.2 Carefully slide the flexible graphite gasket along the pump shaft

and seat uniformly against the drive collar.

To first obstruction

Seal housing bore to have 3.2 μm

(125 μinch) R finish or better

Sleeve or shaft finish to be

0.8 μm (32 μinch) R or better

a

a

Shaft or sleeve OD

+0.000 mm (+0.000 inch) API 610/682

-0.025 mm (-0.001 inch) DIN/ISO

• Bearings must be in good condition

• Maximum lateral or axial movement of shaft (end play) = 0.25 mm (0.010 inch) TIR

• Maximum shaft runout at face of seal housing = 0.05 mm (0.002 inch) TIR

• Maximum dynamic shaft deflection at seal housing = 0.05 mm (0.002 inch) TIR

Face of seal housing to be square to the

axis of the shaft to within 0.0005 mm/mm

(0.0005 inch/inch) of seal chamber bore TIR

and have a 1.6

μ

m (63

μ

inch) R finish or better

a

Gland pilot can be at either of these

register locations, concentric to within

0.125 mm (0.005 inch) of shaft or

sleeve OD TIR

Advertising