5 cartridge mounted – Flowserve X Series BW Seals User Manual

Page 6

Advertising
background image

6

• Determine proper seal setting (SS) gap specified in seal assembly drawing.

• Adjust sleeve drive collar position relative to gland to establish proper gap.

• Tighten drive collar set screws.

SS Gap

(from assembly drawing)

5 Cartridge Mounted

5.1 For proper seal installation, you must obtain the correct seal assembly drawing for

your application.

5.2 Inspect pump shaft. Clean and remove any burrs, nicks, scratches, etc., which could

cause damage to gaskets when installing cartridge seal. Ensure gland and sleeve

gaskets are installed. It may be necessary to lubricate the shaft with grease to prevent

damage to sleeve gasket during installation.

5.3 Carefully install the seal onto the shaft and locate against the face of the seal

chamber. Take care not to impact the seal cartridge as damage to internal compo-

nents can occur.

5.4 Orient ports on the seal cartridge as shown on the seal assembly drawing.
5.5 Evenly torque gland bolts/nuts to prevent uneven gland pressure against the seal

chamber.

5.6 Adjust bearings, coupling, and impeller so that the shaft is in its final operating

position.

5.7 Setting Devices

A - Type 1 (none)

B - Type 2 (setting plates)

C - Type 3 (setting blocks)

Type 1 (none)

Figure 4

Advertising