2 isc installation - single seal design – Flowserve ISC Series User Manual

Page 8

Advertising
background image

8

Figure 3

Setting Device

Bearing Frame

Pump

Back

Plate

Figure 4

2 ISC Installation - Single Seal Design

Note: No seal setting measurements are needed to install the seal.

Instructions are for vertically split case end-suction ANSI pumps.

Modification of the procedure may be required for other style

pumps. Consult Flowserve.

2.1 Tools needed for installation:

• An open end wrench for the gland bolt nuts

• 1/8" Allen wrench

(provided)

• 3/16" Allen wrench

(provided)

for sizes >60 mm (>2.500")

Bearing Frame

2.2 Lubricate the shaft or

sleeve lightly with silicone

lubricant unless otherwise

specified.

2.3 Tighten the setting device

cap screws


2.4 Install the complete ISC

cartridge assembly onto the

shaft or sleeve with the

setting devices near the

bearing housing.

See Figure 3.

2.5 Install the

pump back

plate (seal

chamber) and

bolt it in place

on the bearing

frame. See

Figure 4.

Advertising