4 seal assembly – Flowserve RIS Seal User Manual

Page 5

Advertising
background image

5

10 adjusting stud is mounted to the bearing housing. If your pump is

this type, mount 101 clamp ring, 9 jam nuts and 10 studs to the bearing

housing at this time.

3.4.2 If OEM pump parts are modified in lieu of a new 46 cover,

install 139 end plate leaving 40 bolts loose at this time

(if used), 10 adjusting studs, 101 clamp ring and 9 jam

nuts to the modified parts as shown on the form drawing.

3.4.3 Install assembled 46 cover or modified pump parts on the

pump and tighten the attaching bolts hand tight. Slide the

appropriate centering tool on the shaft and through the

opening in the seal cover until it slips into the cover bore.

Wrench tighten the cover attaching bolts to lock the cover

in place. If a centering tool is not available, use a dial

indicator and center the cover manually within 0.381 mm

(0.015 inch) total indicator reading. See Figure 4.

4 Seal Assembly

Install Assembled Cover or Modified Pump Parts

Figure 4

Centering Ring

4.1 Assemble the stationary face assembly to the seal carrier. See

Figure 5.

4.1.1. Insert drive pins in the stationary face assembly 14 .

4.1.2. Align the drive pin holes in the stationary face assembly

14 with the drive pins in the carrier 240 and assemble

the parts until fully seated.

4.2 Install 71 O-ring (liberally coat with silicon grease) in the O-ring

groove of 46 cover or modified pump parts. Hand tighten end plate

139 bolts.

46 Cover

Advertising