3 Seal Operation

To assure reliable noise free operation of this sealing product,

the following operating guide must be observed.
3.1 Maintain barrier fluid flow and pressure. Begin and confirm

Plan 54 barrier flow at least five minutes before starting the shaft.

This insures that all high point cavities are properly wetted and

delivering lubricant to the rubbing surfaces within the seal.

3.2 Do not exceed the maximum barrier pressure specified

for the seal design.

3.3 Do not exceed the maximum vessel pressure. Make sure

the vessel pressure does not exceed the barrier pressure.

3.4 Do not exceed the maximum vessel temperature specified

for the application. This could exceed the temperature limits

of the materials of construction of the seal.

3.5 Do not rotate the mixer shaft during SIP if steam is injected

into the Plan 54 barrier cavity. Steam is not an adequate

lubricant for the rubbing surfaces.

4 Repairs

This product is a precision sealing device. The design and dimension

tolerances are critical to seal performance. Only parts supplied by

Flowserve should be used to repair a seal. To order replacement parts,

refer to the part code and B/M number. A spare backup seal should be

stocked to reduce repair time.
When seals are returned to Flowserve for repair, decontaminate the

seal assembly and include an order marked "Repair or Replace."

A signed certificate of decontamination must be attached.
A Material Safety Data Sheet (MSDS) must be enclosed for any

product that came in contact with the seal. The seal assembly will

be inspected and, if repairable, it will be rebuilt, tested, and returned.