Step 7 Observe the length of the

lock pin outside of the gland.

The pin should extend 2.5 to

4.8 mm (0.10 inch to 0.19 inch)

from the gland. If it is more or

less than this, remove the gland

and recheck the installation.

Step 8 Pry off the centering devices

with a screwdriver.

Step 9 Connect the flush line to the gland if required.

Step 10 Turn the shaft by hand as a final check to be sure nothing is binding.

2.5 to 4.8 mm

(.10-.19 inch)

Step 7

Step 8