1nomenclature, Figure 1, Table 1 – Flowserve ISC2PP User Manual

Page 2

Advertising
background image

2

© Copyright 2000 Flowserve Corporation

1

Nomenclature

Notes: - Inboard stator (3A) is interchangeable with outboard stator (3).

- Inboard mating ring (3C) is interchangeable with outboard mating ring (3B).

- Inboard stator carrier (SC1) is interchangeable with outboard stator carrier (SC).

- Primary seal O-rings (P, P1, P2, P3, 6, 6A) are all the same size and cross section.

Figure 1

SL

6A

P3

SC1 RR

M

1

C

P

3C

3A

3

13

9

SC

P2

6

14

1B

C1

P1

G

G1

M1

11A

3B

K

CT

13A

B

11 10A

3

Outboard Stator

3A

Inboard Stator

3B

Outboard Mating Ring

3C

Inboard Mating Ring

C

Outboard Springs

C1

Inboard Springs

SC

Outboard Stator Carrier

SC1

Inboard Stator Carrier

P

Outboard Dynamic O-ring

P1

Inboard Dynamic O-ring

P2

Outboard Stator O-ring

P3

Inboard Stator O-ring

6

Outboard Mating Ring O-ring

6A

Inboard Mating Ring O-ring

G

Gasket

G1

Inner Gland O-ring

Table 1

1

Gland Assembly

B

Carbon Bushing

1B

Inner Gland

14

Rotor Carrier

RR

Retaining Ring

CT

Centering Tab

K

Centering Tab Cap Screw

SL

Sleeve Assembly

10A

Drive Ring

M

Outboard Vibration Dampner

M1

Inboard Vibration Dampner

9

Sleeve Collar

13

Cup Point Set Screw

13A

Quarter Dog Set Screw

11

Shaft O-ring

11A

Rotor Carrier O-ring

These instructions are written for trained, experienced technicians familiar with the basic
principles and tools involved in the installation, care and service of mechanical seals and seal
support systems. A complete reading of these instructions by personnel in contact with the
equipment is essential to safety. Incorrect installation, operation or maintenance can result in
personal injury or death to personnel and damage to the equipment.