Seal gard i, Figure 1 – Flowserve Seal Gard User Manual

Page 3

Advertising
background image

• A bypass may be installed from the supply line to the line to the seal to

maintain a flush to the seal during cleaning of the Seal Gard.

1.4 Remove the plastic pipe plugs from the Seal Gard and pipe the seal flush

liquid to the SUPPLY female 1/4 inch NPT fitting on the bottom front of

the Seal Gard.

use caution, do not strip the threads in the acrylic body of the Seal

Gard.

1.5 Pipe the seal flush liquid from the female 1/4 inch NPT fitting of the

check valve fitted to the TO SEAL tap on the bottom back of the Seal Gard

to the flush tap of the Flowserve seal gland. (In the case of packing, pipe

to the lantern ring tap of the stuffing box housing)

3

Seal Gard I

Figure 1

Supply of Clean Flush

Single Flowserve Seal (PSS II with Split Flow

Reducer, ISC, MSS, SL-5000, etc.)

Durametallic

®

4

10

20

GPH

H

2

O

100

PSI/kPa

50

Seal Gard

I

LPM

H

2

O

15

30

To gland flush tap, flush

mixes with pumped fluid

Pressure gauge

Clean-out

Supply flow

control valve

Flow

Float

Flow Reading

Check

valve

On/off supply

Alarm probe option