5

SL-5200 Buffer Fluid System Recommendations

Figure 2

RPM

1800

1500

1200

900

32 to 50 mm

(1.25 to

2.000 inch)

53 to 76 mm

(2.125 to

3.000 inch)

80 to 102 mm

(3.125 to

4.000 inch)

105 to 127 mm

(4.125 to

5.000 inch)

130 to 152 mm

(5.125 to

6.000 inch)

External Flush or

Consult Flowserve

Thermal Convection

System with Plain

Supply Tank

Consult

Flowserve

Consult

Flowserve

Circulating Feature and Supply

Tank with Cooling Coil

Shaft or Seal Size

Notes
1. Recommendations are for use with a water buffer fluid only.
2. These recommendations apply to products having a maximum

temperature of 71°C (160°F).
3. Systems can be applied at the seals maximum pressure limit

according to PV curve 2D-255497.
4. In most cases other systems can be successfully applied.

Consult Flowserve for other options.