Install pump backplate

Figure 3

2 P-200 Seal Installation

Tools needed:

Open-end wrench for gland nuts

Allen wrenches provided

Silicone lubricant provided

2.1 Lubricate the shaft or sleeve OD lightly with the silicone lubricant

provided and slide the complete P-200 cartridge seal onto the

shaft, with the end with the setting devices toward the bearing

housing.

2.2 Install pump back plate (seal chamber/stuffing box), Figure 3.

Position the P-200 seal gland flush connection, port a in Figure 4,

in the 3 o’clock position for normal installations with CW rotation

(9 o'clock for CCW rotation) for optimum heat removal. Alternate

positioning of the gland may be necessary with some pump designs

to permit seal piping to clear the bearing housing. Refer to the

assembly drawing that is supplied with the seal for proper position-

ing. Bolt the back plate in place on the bearing housing.