Introduction – Flowserve V-376 R4 Edward Valves User Manual

Page 4

Advertising
background image

5

Flow Control Division

Edward V

alves

Introduction

This manual is provided to help you

ser
vice your Edward Forged Steel valves.

Before disassembling any valve, we recom-

mend that you check the valve identifica-

tion plate and note size, figure number

and pressure class, so that you can identify

it in the appropriate Edward V

alve catalog.

This catalog will show typical cross sec-

tions to help identify the various par

ts.

Typical Identification Plates

Tools

Most Edward Forged Steel valves may be

readily disassembled with ordinar

y hand

tools. For the removal of screwed-in valve

seats, a special wrench may be necessar

y.

Disassembly

Be sure line is not under pressure when dis-

assembling valves

Bolted Bonnet

In bolted bonnet/cover style valves, cap

screws should be removed (see page 3

and below). The bonnet assembly or cover

can then be removed and the interior of

the valve exposed.

Fig. 238

Bolted Cover Strainer

Screwed Bonnet

Small valves of the screwed bonnet type

are disassembled by unscrewing the

bonnet.

Screwed Bonnet Construction

Advertising