Operation

The numbers in parentheses refer to Hypregun-Plus 5G parts as
illustrated on pages 5 and 6 of this manual.

1.

The air coupler (17) will be found attached to the nipple (7)

as shown in Section A-A. The air hose connector should be

connected to the air supply hose.

2. Fasten the can shield (72, Figure 1) in place around the five-gallon

(18.9 liter) sealant can below the reinforcing rib and with the can

seam covered by the retainer.

3. Slightly mound the sealant in the container so that the concave

shaped follower plate can be brought down on the sealant with a

minimum entrapment of air.

4. Raise the pump mechanism and sealant follower plate prior to

inserting the sealant container into the gun. By connecting the air

supply hose to the air supply nipple (57, Figure 2) in the base of

the pump and opening the ram needle valve (8, Section A-A) the

follower (34, Figure 1) will rise sufficiently to clear the top of the

sealant container.

5. Place the can with the can shield in the operating position in the

Hypregun-Plus 5G. The relief valve tested on the follower plate

can be left open initially to quickly remove air trapped between

the follower and the sealant in the can. It should be closed once

the follower makes contact with the sealant in the pail to ensure

proper priming of the down tube and to prevent sealant from

accumulating on top of the follower plate.

6. Be sure the valve screw (63, Figure 1) in the pump body is

closed. Connect the air supply hose to the nipple (7, Section A-A).

The ram needle valve should be opened slowly causing the air

pressure to force the follower plate (34, Figure 1) down toward

the sealant container.

a

CAUTION: Keep fingers clear as the follower plate

descends into the sealant container.
Care should be exercised that the sealant container is directly

under the follower plate as the two are brought into contact. Once

the follower plate has entered the top of the sealant container,

open the ram needle valve 2

1/2

turns from closed position.

7. As shown in Section B-B, the relief valve (64) is opened fully

while the valve screw (63, Figure 1) is opened two turns.

8. With the air motor throttle valve closed (3, Figure 1), allow the

column between the sealant container and relief valve (64, Section

B-B) to fill with sealant with the pressure of the follower plate

alone. After a steady flow of sealant is obtained at the relief valve,

open the throttle valve and pump sealant through the vent valve

until there are no air bubbles. (If the available line pressure is not

sufficient to push sealant through the relief valve by the follower

plate pressure alone, open the air motor throttle valve before the

sealant comes out the vent valve.)

9. After venting of the air is complete, close the valve screw (63,

Figure 1) and the relief valve (64, Section B-B) and read the

pressure gauge (65, Figure 1). If the pressure gauge does not

read several thousand pounds sealant pressure, the relief valve

(64) and the valve screw (63) should be opened again to allow

further venting. Repeat this operation as required. Occasionally,

the Hypregun-Plus 5G may become air bound during operation.

If this occurs, repeat the procedure for air venting as outlined

above.

10. With the shutoff and relief valve (78, Section B-B) in the closed

position, the button head coupler (69, Section B-B) should be

slipped over the button head fitting on the valve to be injected.

Open the shut-off valve (a small wrench may be required). Adjust

the air throttle valve (3, Figure 1) on the air motor and observe

sealant pressure on the gauge (65, Figure 1) to ensure proper

sealant flow and pressure for plug valves.

a

WARNING: High pressure injection of sealant into low

pressure iron and semi-steel bodied valves may deform or

destroy certain valve parts which could result in personal

injury. Follow the valve manufacturers recommended

procedures for sealant injection.

11. After the valve is injected with sealant, close the shutoff and

relief valve (78, Section B-B). Remove the button head coupler

(69, Section B-B) from the fitting on the valve. This may be done

without turning off the air supply to the air motor. By using the

shut off valve, the user can attach the coupler or remove it from

the fitting with the gun retaining positive pressure.

12. When all of the sealant has been pumped from the sealant

container, close the throttle valve (3, Figure 1) and transfer the air

supply hose to the air supply nipple (57, Figure 2) on the base of

the gun. With the ram needle valve (8, Section A-A) open, the gun

mechanism is raised, lifting the sealant container off of the gun

base. Close the ram needle valve.

13. Unclip the can shield and remove. Remove the can from the

follower. It may be necessary to attach the air supply to the relief

valve nipple (57, Section B-B) and slowly open the relief valve (64,

Section B-B) 1/4 turn to allow air to enter the can. The can will be

forced from the follower. Additionally, air can be connected to the

follower plate relief valve nipple (57, Figure 1).

14. In changing from one service sealant to another, it is advisable to

purge the gun sealant system. To do this, pump the new sealant

through the delivery hose, with the coupler removed, until the old

sealant has been purged.