8

®

User Instructions Mach 1 High Performance Plug Valve - DVENIM0300-01 - 03.13

TABLE IV-A-II

*Apply Loctite® 242 to fastener threads, top cap only.

TORQUE REQUIRED ON TOP CAP FASTENERS OF CLASS 150 MACh 1 VALVES

TABLE V-A-III

*Apply Loctite® 242 to fastener threads, top cap only.

TORQUE REQUIRED ON TOP CAP FASTENERS OF CLASS 300 MACh 1 VALVES

TABLE V-A-IV

*Apply Loctite® 242 to fastener threads, top cap only.

TORQUE REQUIRED ON TOP CAP FASTENERS OF CLASS 600 MACh 1 VALVES

TABLE V-A-V

TORQUE ON PLUG ADJUSTER OF MACh 1 VALVES, 150#, 300# AND 600#

SECTION V

17. Place the locking stop (Part 12) on the top cap as shown in

Figure V-A7 and tighten the locking stop fasteners (Part 13) to

a reasonable torque. Check their orientation based on the loca-

tion marks made during disassembly (Section III, step 1).

FIGURE V-A7

18. Place the stop collar (Part 14) and retainer (Part 15) on the

plug stem as shown in Figure V-A8. The stop collar should

point in the direction of the flow. Check the orientation based

on the location marks made during disassembly (Section III,

step 1).

FIGURE V-A8

19. The valve should turn clockwise to close. The valve is now

ready for test and use.

20. LEAK TESTING: Anytime a valve has been modified in any

manner, including fastener changes, it must be re-tested.

Normal testing, using gas, should be at 80 PSI for Class

150 through Class 600. Refer to API or MSS for test proce-

dures complying with these specifications.

Valve sizes

1"

1.5"

2"

3"

4"

6"

Max. Torque (ft-lbs)

10

10

15

28

40

80

Valve sizes

1"

1.5"

2"

3"

4"

6"

Max. Torque (ft-lbs)

12

12

22

35

62

115

Valve sizes

1"

1.5"

2"

3"

4"

6

"

Max. Torque (ft-lbs)

14

20

35

45

42

70

Valve sizes

1"

1.5"

2"

3"

4"

6

"

Max. Torque (ft-lbs)

35

35

35

50

75

150