Suggested Care

The following suggestions will ensure efficient

and continued operation of the 400-D Hand Gun.

1. Do not carry the gun by the Handle unless

secured with the Carry Strap. Carrying the gun

with an unsecured handle can damage the Piston.

2. Keep the Piston area of the gun free of debris.

3. Do not unscrew the By-Pass Valve more than one

complete turn. Doing so may allow air to enter the

hydraulic system of the gun.

4. Protect the Gauge from damage.

Maintenance

If the operating instructions are carefully followed and hydraulic

fluid is added at regular intervals, the 400-D Hand gun will operate

indefinitely without further maintenance. It is recommended a

maintenance program be established where the number of hours

the gun is used determines when maintenance is required.

Note: Numbers in parentheses refer to parts as illustrated

on pages 6 and 7 of this brochure.

Recharging and Bleeding

the Hydraulic System of Air

1. Open the By-Pass Valve (12) and remove the Handle (1).

2. Remove the Sealant Barrel Cap (26) and stand

the gun with the Sealant Barrel (24) up.

3. With the Handle, press the Floating Piston (41)

to the bottom of the Sealant Barrel. Make sure the

Floating Piston bottoms out in the Sealant Barrel.

4. Leave the Handle inside the Sealant Barrel and turn

the gun so the sealant barrel is pointing downward

and remove the Fluid Bag Barrel Cap (23).

5. Slowly remove the Screw (46) and O-Ring (31) from

the Fluid Bag (32).

6. Allow the weight of the gun to rest against the Handle

and slowly fill the Fluid Bag with Nordstrom

Hydraulic Fluid 71251. Allow the gun to stand 15 minutes to

permit the air suspended in the fluid to escape. (It is

recommended to allow the gun to sit for 2 to 3 hours after

recharging the hydraulic system with fluid to allow the

Fluid Bag to regain its original shape.)

7. Replace the Screw and O-Ring, being careful not to

entrap air.

8. Remove the Handle and replace the Fluid Bag Barrel Cap.

9. Reload the Gun with Sealant and replace the Sealant

Barrel Cap.

Replacing the Hydraulic Fluid Bag

1. Remove the Handle (1), open the By-Pass Valve (12)

and push the Floating Piston (41) to the bottom of the

Sealant Barrel (24). Clean the Handle and replace.

2. Place the Fluid Bag Barrel (22) end of the gun in a vise.

3. Place a suitable size container below the vise to catch

hydraulic fluid.

4. Using Gun Assembly Wrench 47521, remove the Body

(6) and attached parts from the Fluid Bag Barrel.

Hydraulic fluid will spill from the Fluid Bag.

5. If the Floating Piston could not be returned to the bottom of

the Sealant Barrel, return it now. See Step 1.

6. Remove the damaged Fluid Bag (32) from the Fluid Bag Barrel

and clean the barrel.

7. Remove the Sealing Ring (21).

8. Place the Sealing Ring onto the new Fluid Bag, loosen the

Fluid Bag Screw (46) and tighten snug.

9. Place the Fluid Bag into the Fluid Bag Barrel.

10. Fill the Fluid Bag to within ¾" of the top with Nordstrom

Hydraulic Fluid 71251.

CAUTION: Take care to keep foreign matter

from entering the hydraulic fluid. Debris in

the hydraulic system can prevent the gun

from operating properly.

11. Replace the gun assembly removed in Step 4 and tighten

by hand.

12. Tighten the assembly to approximately 50 ft-lb using the

Gun Assembly Wrench.

CAUTION: Overtightening the Fluid Bag Barrel to the

Body may damage the Fluid Bag Assembly.

13. After equipping the gun with a new Fluid Bag, recharge the

gun with hydraulic fluid as described in this brochure.

Sealant Barrel Replacement

1. Open the By-Pass Valve (12) and push the Floating

Piston (41) to the bottom of the Sealant Barrel (24).

2. Close the By-Pass Valve.

3. Place the Sealant Barrel end of the gun in a vise and,

with Gun Assembly Wrench 47521, remove the Body

(6) and attached parts from the Sealant Barrel.

4. Remove the Sealant Barrel from the vise and push

the Floating Piston from the Sealant Barrel. Note

the position of the assembly when removing.