Worcester control valves – Flowserve TB59 User Manual

Page 3

Advertising
background image

06784-E

3

closed position. Rotate stem and ball to open position.
Carefully insert new separate body seals (if used) and place
center section between pipe end and tank bottom flange.
Replace and tighten body bolts per torque figures and method
found in Sect. A.2.e

CAUTION: Do not scratch body seals when replacing valve
body.

When ordering parts, please provide the part name and the following
information as found on the valve nameplate or mounting bracket
nameplate:

1. Valve Size, Style and Revision Number – Example: 1" TB59 66T

SE RO Stem

2. Valve Size, Style and Five-Character Code, known as a “P”

Number, “T” Number, “C” number, or similar, the designation for a
non-standard product.

Example:

1" TB59 66PT SE TO244 Ball

The terminology shown in the exploded view Parts Listing below is
standard.

Flow Control Division

Worcester Control Valves

Advertising