Worcester controls – Flowserve TB59 User Manual

Page 3

Advertising
background image

06798-D

Tank Bottom Valves: 2"–4" TB59 Installation, Operation and Maintenance

3

g. Place center section between pipe end and tank bottom flange,

then replace body studs and nuts and torque to figures in
paragraph A.2.e.

After the valve is assembled it should be cycled a few times to
ensure that the valve operates smoothly with no chattering of the
ball. The normal operation is an initial high torque to “break”
from the closed position to a smooth running lower torque mid-
cycle, to a high torque at the end of the 90° cycle or open
position. The torque is similar when closing.

When ordering parts, please provide the part name and the following
information, as found on the valve nameplate.

1. Valve Size, Style and Revision Number:

Example: 3" TB59 66RTSE RO STEM

2. Valve size, style and five-character code, known as a “P” number,

“T” number, “C” number, or similar number, the designation for a
non-standard product:

Example: 4" TB59 66RTSW T0244 Ball

The terminology shown in the parts listing below is standard.

Flow Control Division

Worcester Controls

Retaining Nut

Belleville Washers (2)

Follower

Stem Seal Protector

Stem Seals (3)

Centering Washer
(not used on 2" valves)

Seat (2)

Seat Retainer
(not used on 2" valves)

Body Seal (2)

Thrust Bearing

Advertising