9.0 MAINTENANCE INSTRUCTIONS (Continued)

9.1.1

Disassembly (Continued)

(h)

Loosen the gland retainer setscrews (220) until they do not make contact with the gasket retainer

(033). Then turn the gland retainer (131) counterclockwise off the bonnet (002). Turn the gasket

retainer (033) out of the body (001). If the bonnet (002) drops and turns with the gland retainer,

grasp the stem (025) and lift to hold the bonnet, thus preventing it from rotating.

(i)

Remove the pressure seal gasket (030) by carefully lifting the bonnet (002). It is imperative

that the bonnet be lifted over the stem as straight as possible to eliminate the possible scoring of

the stem. If the bonnet is wedged into position, carefully lift up on the stem until the gasket and

bonnet come free.

(j)

The stem (025) and discs (004A and 004B) can now be lifted from the valve body. As the discs

rise above the guides in the valve body, they should be retained to reduce the possibility of them

becoming damaged by falling on the lapped surfaces.

(k)

Remove the discs (004A and 004B) from the stem (025) and place them where they will not be

damaged or scratched.

(l)

At this time, the discs and seat rings may be lapped, if required. The sealing surfaces should be

inspected to determine if scratches or minor imperfections can be corrected by lapping and/or if

replacement parts are necessary (refer to Paragraph 9.3 for lapping instructions).