G4, G4ZHF AND G4R USER INSTRUCTIONS ENGLISH 5-14

8. The thrust collar (Part 11)

is then assembled over the

plug stem and driven into

place through the use of the

thrust collar guide, part series

#BY77545A, and arbor

press (Figure VI-6).

6. The metal diaphragm (Part 6A) is placed over the plug

stem and the hole enlarged just enough to slip down on

the stem (Figure VI-3).

7. A thin coat of silicone oil is applied to the down edge of

the metal diaphragm. The diaphragm is then placed over

the plug stem with the lip down (Figure VI-4).

8. The Grafoil packing ring (Part 20) is placed over the stem

(Figure VI-5).

9. The thrust collar (Part 11) is then assembled over the

plug stem and driven into place through the use of the

thrust collar guide and arbor press (Figure VI-6). Place

the plug (Part 2) into the body in the open position.

10. The Grafoil top cap gasket (Part 21) is to be installed

with the tapered or small edge diameter down or placed

against the valve counterbore. The plug is pushed down

until it is flush with the bottom of the body port in order

to check the diaphragm fit inside the Grafoil gasket for

clearance. The PFA diaphragm must not ride on the

Grafoil gasket but should fit just inside the Grafoil.

11. The top cap (bonnet) (Part 3) and adjuster assembly is

installed and the plug is pushed down in the open posi-

tion again until the bottom of the port is flush with the

body part and the top cap bottoms firmly on body coun-

terbore. The top cap must be checked before installation

to ensure there is no chamfer on outside edge of the cap.

The inside edges are to have a break corner chamfer only.

12. The top cap is visually located to be evenly spaced inside

the body counterbore. The side of the top cap compres-

sion flange is equally spaced with the side wall of the

body counterbore. Fasteners should be installed and

tightened to 5 ft-lb torque to prevent movement of the

cap during initial torquing.

13. While continuing to hold the open plug in a flush condi-

tion with the body, the top cap fasteners (Part 3A) are

torqued in 50 ft-lb increments. Tighten in a crisscross

method to the following values using a calibrated torque

wrench. The adjuster fasteners (Part 12A) are completely

loosened for this step.

Size

Torque

6"

125 ft-lb

8"

115 ft-lb

14. The top cap (Part 3) is then relieved from compression

and removed. The Grafoil gasket (Part 21), PFA

diaphragm (Part 6), metal diaphragm (Part 6A) and

Grafoil packing ring (Part 20) are visually checked for

misalignment.

SECTION VI
ASSEMBLY SPECIFICATIONS – FIRESAFE VALVES G4Z, G4ZHF, G4ZR

FIGURE VI-6

Packing and thrust collar driven

into place.

GASKET

FIGURE VI-7

Grafoil gasket placed on metal dia-

phragm using a bonding material.

9. The entire assembly

is turned over and the

Grafoil gasket placed on

the metal diaphragm

(Figure VI-7). A small

amount of rubber cement

is placed on the Grafoil

in several places to cause

it to ad here to the metal

diaphragm.

10. Continue to assemble the valve per Step 8 of Section V A

for the

1

/

2

"–

3

/

4

" size valves or Section V B for the 1"–4".

6"– 8"

Due to the tooling and associated equipment required

(presses, fixtures, etc.) to handle 10"–14" size valves, it is

highly recommended they be returned to the factory for repair

and rebuild.
1. Normal procedures for field replacement of one-piece

sleeves are to be followed for inserting the sleeve Section

V B, steps 1–4.

2. The firesafe top seal assembly differs from the stan dard G4

top seal and is completed per the following instructions.

3. The PFA diaphragm (Part 6) is to be flared on a tapered

bar just enough to slip over the plug stem (Figure VI-1).

4. The PFA diaphragm is placed over the plug stem with the

lip down (Figure VI-2). The plug stem should be checked

for nicks before installing the PFA diaphragm. Nicks on

this surface could result in scratches on the lip of the

diaphragm.

5. The thrust collar (Part 11) and thrust collar guide, part

series #BY77545A, are to be installed over the plug stem

and loaded by an arbor press to flatten the PFA firesafe

diaphragm. Remove the thrust collar and thrust collar

guide.