Technical data

Nominal size
DN/NPS 40 mm (1½" BSPP*)

Operating pressure
10 barg (145 psig)

Operating temperature
–30 °C to + 205 °C

Test pressure
15 barg (218 psig)

Tank connection
Flat face square flange

Hose connections
1½" BSPP* male thread
¼" NPT or BSPP*) for connecting pressure gauge

Materials
316 SS
Body: 1.4408/316C16-BS 1504 (identical) CF8M
Wetted parts: austenitic steel with molybdenum / austenitic-ferritic steel
Seat: PTFE
Stem seal: PTFE

Dimensions and connections
See data sheet

Kv value (flow coefficient)
Based at DN 40: 219 m³/h

Weight
Approx. 2.3 kg

Operating forces
Handlever: approx. 10 N

Operating angle of handlever
Standard design: approx. 90°

*) BSPP = British Standard Pipe Parallel Thread

Corrosion resistance

When used for its intended purpose the safe functioning of the valve will not be impaired by corrosion.

Sizing

The valve body must not be subjected to sharp increases in pressure. Flanges are designed to withstand dynamic
loading (bending and alternating stress). The dimensional allowances for corrosion reflect the latest state of
technology.

Installation

Danger

After removing the transit protection the valve ball and seals might drop out of the valve body.
This presents the risk of injuries to arms, hands and feet.

For installation place the airline valve in the

OPEN