Maintenance, Item – Flowserve BK 15 User Manual

Page 13

Advertising
background image

13

Maintenance

– continued –

WINIX

®

2150 is a registered trademark of WINIX GmbH, Norderstedt

1. Take notice of note “Danger” on page 6.

2. Undo hexagon bolts . Remove cover from the body .

3. Remove regulator .

4. Remove and clean strainer .

5. Clean body, internals and all gasket surfaces.

6. Apply heat-resistant lubricant to all threads and the seating surface of the nozzle

insert and the cover (use for instance WINIX

®

2150).

7. Insert strainer .

8. Screw in regulator and tighten with a torque of 140 Nm.

9. Insert new gasket .

10. Place cover onto the body. Tighten hexagon bolts alternately and in several

steps to a torque of 45 Nm.

Clean/Replace Strainer

N

D

K

N

J

Spanner A. F. 18 mm to DIN 3113, form B

Torque spanner 20 – 160 Nm to DIN ISO 6789

Tools

G

H

H

Torques

Item

Designation

Torque [Nm]

Regulator

140

Hexagon bolts

45

Union nuts

30

All torques given in the table are based at a room temperature of 20 °C. Threads without lubricant.