background image

5

Flow Control Division

Kammer Control Valves

REMOVE AND INSTALL ACTUATOR

General Information
We recommend separating the actuator from the
valve during all repair work. However, many
maintenance and adjusting operations can be
carried out in an installed condition.

6.1

Remove series 4 actuator
(see Fig 1 + 2)
For series 2 actuator see 6.3

For actuators with spring-to-close, go to 6.1.1
For actuators with spring-to-open, go to 6.1.2

6.1.1

Shut off air supply.

WARNING:

Depressurise the line to atmospheric

pressure and drain all fluids from the valve before
working on the actuator. Failure to do so can cause
serious injury.

6.1.2

Remove cap and nameplate. Tighten zero adjusting
nut until it just touches the surface of the spring
housing. This relieves the plug from actuator spring
pressure. If the actuator is fitted with a handwheel
this can be used to relieve the plug from actuator
spring pressure.

6.1.3

Using a wrench, secure the actuator stem against
turning and using a second wrench loosen the stem
locknuts. If the actuator is fitted with a coupling re-
fer to the procedure described in the maintenance
instructions for the I/P actuator.

CAUTION:

The actuator stem must not be rotated,

as this will cause damage to the diaphragm.

6.1.4

Loosen gland and clamp nuts.

6.1.5

Secure plug stem against turning and unscrew ac-
tuator from plug stem by rotating counter-clock-
wise.
CAUTION:

Ensure that the plug assembly is not ro-

tated with the plug seated. This may cause irrepa-
rable damage to the seating faces.

6.1.5

Remove actuator and remove at the same time lock-
nut, travel indicator disc, gland nut and clamp nut.

3.2

Install series 3 actuator

Information:

Before the actuator is installed, it must be cali-

brated according to section 3 of the instructions
„Pneumatic and Electro-pneumatic Actuators“.

All worn or damaged parts must be replaced.

Reusable parts must be clean.

6.2.1

Position actuator with clamp nut, gland nut, lock-
nuts and travel indicator disc on the valve.

6.2.2

Only for „spring-to-close“ actuators:
Screw actuator onto plug stem by rotating clock-
wise, until the yoke plate just touches the valve hous-
ing and the actuator is aligned forward. If the ac-
tuator is fitted with a coupling refer to the proce-
dure described in the maintenance instructions for
the I/P actuator.

CAUTION:

Ensure that the plug assembly is not ro-

tated with the plug seated. This may cause irrepara-
ble damage to the seating faces.

Only for „spring-to-open“ actuators:

Lift plug stem and screw it into the lower coupling
half until the distance between „plug in seat“ and
„plug raised“ approximately corresponds to the speci-
fied stroke.

6.2.3

Tighten clamp nut and gland nut.

6.2.4

Adjust seat tightness by screwing/unscrewing the
plug stem in/out of the actuator stem.

CAUTION:

Ensure that the plug assembly is not ro-

tated with the plug seated. This may cause irrepara-
ble damage to the seating faces. Open valve, make
adjustment, close valve and check for leaks. If the
valve is fitted with a bellows seal the plug stem may
NOT be rotated at all. In the case of a bellows seal
adjustments are made with the coupling.

6.2.5

After adjusting, secure the locknuts and the travel
indicator disc lying between them against actuator
stem and align the travel indicator on the yoke rod.

6.3

Remove series 2 actuator
(see Fig. 1a)
For series 4 actuator see 6.1

6.3.1

Shut off air supply.

WARNING:

Depressurise the line to atmospheric

pressure and drain all fluids from the valve before
working on the actuator. Failure to do so can cause
serious injury.

6.3.2

Disconnect all tubing.

6.3.3

Remove 2 screws and remove coupling.

6.3.4

Remove yoke rod retaining nuts and lift actuator
assembly from the valve.

6.3.5

Remove coupling insert and it’s locknut from plug
stem.

NOTE:

Ensure that the plug assembly is not rotated

with the plug seated. This may cause irreparable
damage to the seating faces.

6.4

Install series 2 actuator

(see Fig. 1a)

The actuator stem must be fully extended:
Actuators with air-to-open action must be fully

vented. Actuators with air-to-close action apply
supply pressure.

Manually depress the plug stem to ensure the plug is

fully seated.

6.4.1

Screw coupling insert locknut and coupling insert as
far as possible onto plug stem.

6.4.2

Place the actuator assembly on the valve engaging
the yoke rod threads in the lower yoke plate and
ensuring the actuator faces in the correct direction.

STOP!

STOP!

Advertising