Technical data – level probe

Weight
Level probe approx. 5.6 kg
Welding standpipe approx. 4.5 kg

Technical data – preamplifier

Case
Terminal box made of aluminium, painted

Wiring
Via Harting connector with 6 terminals
Cable gland PG 11

Supply voltage
12 V DC, 30 mA

Output
1 – 10 V DC, measuring voltage U

M

Protection
IP 54 (DIN 40050)

Admissible ambient temperature
70 °C

Supply cable for electrode
Screened three-core cable, conductor size 0.5 mm², max. length 500 m

Technical data – probe

Connection
Probe flange PN 320 with welding standpipe for pipes DN

100; with tee piece or for

pipes DN > 100 with lateral penetration

Materials for wetted parts
Protection tube up to 500 °C

St 35 (1.0305)

Protection tube up to 550 °C

10 CrMo 9 10 (1.7380)

Strainer

X 6 CrNiMoTi 17-12-2 (1.4571)

Insulting seal of probe rod

Special ceramics material

Flange joint ring

X 6 CrNiTi 18-10 (1.4541)/silver

Max. admissible pH value
10 (for ceramics insulation)

Temperature sensor
Pt 1000

Pressure/Temperature ratings

Material for flange/welding standpipe

1.5415

1.7380

1.4922

Admiss. service pressure

[bar]

4

320

2

200

320

2

200

4

320

3

230

[psig]

4642

2901

4642

2901

4642

3336

Admiss. service temperature

[°C]

4

120

2

450

120

2

500

4

120

3

550

[°F]

4

248

2

842

248

2

932

4

248

1022

Advertising