Electrical Specifications

Model

Agency Approvals

Hazardous Location

Rating

1

Max Voltage

(vdc)

Min. Voltage

(vdc)

Max. Current

(mA)

W7000

None

None

N/A

N/A

N/A

W7100

None

None

30 vdc

6 vdc

150 mA

W7200

FM

CSA

ATEX/IECEx

(EX) Cl. I Div 1, Gr. B-D
(EX) Cl. I Div. 1 Gr. B-D

(EX) Ex d IIC T4-T6

3

30 vdc
30 vdc

30 vdc

4

6 vdc
6 vdc
6 vdc

150 mA
150 mA

50 mA

4

W7400

2

FM

CSA

ATEX/IECEx

(IS) Cl. I Div. 1 Gr. A-D
(IS) Cl. I Div. 1 Gr. A-D

(IS) Ex ia IIC T6

3

28 vdc

4

28 vdc

4

30 vdc

4

6 vdc
6 vdc
6 vdc

50 mA

4

50 mA

4

110 mA

4

W7500

None

None

30 vdc

6 vdc

30 mA

W7600

None

None

N/A

N/A

N/A

Warning: These instruments must be installed in accordance with local national electrical codes, especially for hazardous
locations. Consult unit label to determine specific unit certifications.
Notes:

1

See hazardous location certificate for detailed temperature ratings. All

Apex W7000 units comply with ATEX

directive for non-electric equipment intended for use in hazardous locations to Ex II 2 G.

2

Additional information regarding entity parameters and instructions for wiring to intrinsically-safe I-P may be found
in separate IOM, as well as in the hazardous location certificate.

3

See hazardous location certificate for special conditions for safe use.

4

Maximum voltage and current considerations may be affected by application specifics, such as choice of barrier,
ambient temperatures, etc. See hazardous location certificate for additional information.