Flowserve MK 36/51 User Manual

Page 24

Advertising
background image

Maintenance

Replacing / Cleaning thermostatic capsule

1. Observe the Important Safety Note.

2. Take the steam trap out of the pipe.

3. Unscrew upper body part from lower body part.

4. Clean thermostatic capsule.

5. Replace thermostatic capsule in case of visible signs of wear or

damage.

6. Press new or cleaned thermostatic capsule onto the lower body part

until it snaps into place.

7. Screw body parts together and tighten with a torque of 100 Nm.

Advertising