background image

PLANNING

GUIDE

Web: http://www.Dacor.com

Corporate Phone: 800-793-0093

Specifications are subject to change without notice.

See installation instructions for additional details.

CI.26

Microwave/Warming Oven

COMBINATION INSTALLATIONS

16 3/4"

(425mm)

“A”

9 1/8"

(232mm)

“B”

1 1/2"

(38mm)

Min.

3/4"

(19mm)

Min.

120V

Microwave

Receptacle

120V Warming

Oven Receptacle

1

1

7/8“ (22mm) Min.

29"

(737mm)

Overall

Stacked

Height

19 1/8"

(486mm)

“A”

9 1/8"

(232mm)

“B”

1 3/8"

(35mm)

Min.

3/4"

(19mm)

Min.

120V

Microwave

Receptacle

1

1

3/4“ (19mm) Min.

31 1/8"

(791mm)

Overall

Stacked

Height

120V Warming

Oven Receptacle

CUTOUT DIMENSIONS

DMT2420 ShOWN

CUTOUT DIMENSIONS

DCM24 ShOWN

Microwave

Model No.

“A” Cutout Width

DMT2420 w/Trim Kit

24 3/8” (619mm)

DCM24 w/ACTK27

25 1/4” (641mm)

DCM24 w/ACTK30

28 1/4” (718mm)

DCM24 w/ACTK36

25” (635mm)

Warming

Oven

Models

“B” Cutout Width

27”

25 1/2” (648mm)

30”

28 1/2” (724mm)

36”

34 3/8” (873mm)

1/1

Revised

08/26/08

All tolerances: +1/16”, -0, (+1.6mm, -0) unless otherwise stated

NOTE:

1. 3/4” (19mm) support platform (flush with cutout).

2. See individual appliance Planning Guide pages to

determine overlays.

3. Spacing between appliances and drawers/doors

shown is minimum required to allow for ventilation

and prevent scraping. Additional space may need

to be added for appearance.