Model 226-002

Mounting and wiring of the Model 226-002 must be in accordance with Div. 2 installation standard
practices.

1. Use a GAI-Tronics Model 233-001 Screwdriver to loosen the eight front panel security screws.

2. Remove the front panel assembly to expose the eight mounting holes. These holes accept 3/8-inch

diameter bolts. The length of these bolts depends on the mounting surface.

For wider and retrofit hole patterns from the Northern Telecom Model NE-2525Q Series, use the
7.875

 4.00-inch hole pattern. Four hole plugs are supplied for the unused holes.

When using the Model 232-001 Pole Mounting Kit, use the 5.25

 4.00-inch hole pattern. This kit

includes four 3/8-16

 1-inch shoulder bolts with Teflon™ seal washers. For additional support

in wood poles, use 3/8-inch or 1/2-inch lug bolts with washers (not included).

For wall-mount applications, mount directly to the wall or use Model 232-001 Pole Mounting Kit
and 3/8 inch or 1/2 inch lug bolts with washers. (N

OTE

: Lug bolts with washers are not included

in the kit).

3. A 1/2-NPT conduit entrance is provided at both the top and the bottom of the unit. An Allen drive

plug is supplied for the unused entry.

Figure 3. Model 226-002 Outline Drawing