Table 14. TB8 Terminal Block Assignments

Terminal Labeled Function

Specification

TB8-1

I

N

-25

Input 25

TB8-2

I

N

-26

Input 26

TB8-3

I

N

-27

Input 27

TB8-4

I

N

-28

Input 28

TB8-5

I

N

-29

Input 29

TB8-6

I

N

-30

Input 30

TB8-7

I

N

-31

Input 31

TB8-8

I

N

-32

Input 32

• Short input terminal to GND if using a Normally Open

activation switch.

• Remove input terminal from GND if using a Normally

Closed activation switch.

TB8-9
through
TB8-16

GND

Ground

Ground reference for input 25-32 terminals

TB4- Power Connections

The I/O Control Module requires a dc power supply. The dc power supply voltage must be between 12
and 24 V dc. TB4 is used for power connections. Please refer to the TB4 terminal block assignment
chart and Figure 6 below.

Figure 6. Power connections at TB4

Table 15. TB4 Terminal Block Assignments

Terminal Labeled Function

TB4-1

+

Power (+) 12 to 24 V dc power supply positive terminal

TB4-2

-

Power (-) 12 to 24 V dc power supply negative terminal