VoIP Flush-Mount Telephones

Figure 9. Model 297-700

Figure 10. Model 298-702

Stanchion or Flush-mount Applications

1. Use the supplied back box to mount the Model 297-700, 297-701, 297-702, 297-703, 298-701 and

298-702 VoIP Telephones in flush-mount applications or in a GAI-Tronics Model 234 Series
Stanchion. Mount the back box to the structure using the appropriate hardware. Refer to Figure 15
cutout dimensions.

2. Remove the tapered plug from the top or bottom cable entry hole in the back box, and install the cable

and cable fitting. See the Field Wire Installation section on page 11.

3. Make hardware configuration changes, if necessary. Refer to page 14.

4. Perform the initial programming of the phone. Refer to the Programming section beginning on page

16. Verify operation by calling to and from another phone.

5. Adjust the speaker levels if necessary. Refer to the Speaker Level section on page 15.

6. Attach the telephone’s front panel to the mounting flanges of the back box using the six supplied

#10-32 tamper-resistant screws and washers.