English – DeWalt N000589 User Manual

Page 12

Advertising
background image

12

English

WARNING: Risk of fire, asphyxiation and burning. NEvER fill fuel tank

when engine is running or hot. Do not smoke when filling fuel tank.

• Never fill fuel tank completely. Fill tank to 1/2" (12.7 mm) below

bottom of filler neck to provide space for fuel expansion. Wipe any

fuel spillage from engine and equipment before starting engine.

• Never run engine in doors or in en closed, poorly ven ti lat ed

areas. En gine exhaust con tains carbon mon ox ide, an odorless

and deadly gas.

• DO NOT let hoses come in contact with very hot engine

muffler during or immediately after use of your pressure

washer. Damage to hoses from contact with hot engine

surfaces will NOT be covered by warranty.

cAutIoN: NEvER pull water supply hose to move pres sure washer.

This could damage hose and/or pump inlet.

• DO NOT use hot water, use cold water only.
• Never turn water supply off while pressure washer engine is

running or damage to pump will result.

• DO NOT stop spraying water for more than two

U

minutes at a time. Pump operates in bypass

mode when spray gun trigger is not pressed.

When the temperature inside the pump rises

too high the thermal relief valve (U) will open

and release a gush of water in an effort to lower

the temperature inside the pump. The thermal

relief valve will then close. If pump is left in bypass mode for

more than two minutes internal components of the pump can

be damaged.

start-uP ProceDure
1. In a well-ventilated outdoor area, add fresh, high-quality, unleaded

gasoline with a pump octane rating of 86 or higher. Do not overfill.

Wipe up spilled fuel before starting the engine. Refer to engine

instruction manual for correct procedure.

2. Check engine oil level. Refer to the engine instruction manual for

correct procedure.

3. Connect the water hose to the water source. Turn the water source

on to remove all air from the hose. When a steady stream of water

is present, turn the water source off.

4. Verify the filter screen (V) is in water inlet of

V

pump. The cone side faces out.

5. Connect the cold water source (X) to pump

inlet.

note: Water source must provide a minimum

of 5 gallons per minute at 20 PSI (138 kPa).

WARNING: To reduce the possibility of con-

tamination always protect against backflow when

connected to a potable water system.
6. Connect high-pressure hose (P) to pump

X

P

outlet.

7. If applying a chemical or cleaning solution,

refer to

chemicals and cleaning

solvents.

8. Turn the water source on.
cAutIoN: Risk of property damage. Failure

to do so could cause damage to the pump.
9. Remove all air from the pump and high pressure hose by depress-

ing trigger until a steady stream of water is present.

10. Start engine. Refer to the engine instruction manual for correct

procedure.

WARNING: Risk of unsafe operation. If engine does not start

after two pulls, squeeze trigger of gun to relieve pump pressure. Pull

starter cord slowly until resistance is felt. Then pull cord rapidly to

avoid kickback and prevent hand or arm injury.

Advertising