02/15

Models 393-700, 393AL-700, and 394AL-702

The mounting and wiring instructions are as follows:

1. Remove the four security screws from the

front panel.

2. Position the enclosure on the mounting

surface. The enclosure provides four
0.28-inch mounting holes in a 7.0

 8.5-inch

hole pattern. Secure the enclosure to its
mounting surface with four ¼-inch diameter
bolts of the appropriate length for the surface.
N

OTES

:

1. When using the GAI-Tronics Model 231-
001 Pole Mounting Kit, follow the mounting
instructions provided in the kit.
2. When mounting outdoors, installation of a
surge suppresser (customer-supplied) on the
Ethernet line is recommended.

3. For Model 393-700 only: Create a conduit

access hole using a Greenlee-type punch that
is equivalent in size to the conduit diameter.
Bottom entry is strongly recommended. Insert
a conduit fitting in the access hole.

4. Install conduit as required. Refer to conduit installation details on page 7.

N

OTE

: Use silicone sealant or equivalent around and inside all conduit entries.

5. Pull the Ethernet cable through the conduit and install the cable as shown in the “Field Wire

Installation” section on page 14.

6. Connect any desired peripheral devices. Refer to page 18 for connection information.

7. Perform the initial programming of the telephone. Refer to the “Programming” section on page 19.

8. Verify operation by calling to and from another telephone. Verify operation of peripheral equipment.

9. Complete the installation by attaching the front panel assembly to the rear enclosure using the four

security screws, 10–12 in-lbs. of torque recommended.

Figure 5. Model 393-700 VoIP Telephone in a