Mounting, Cable entries – GAI-Tronics 352-001 UL Class I Division 1 Telephones User Manual

Page 3

Advertising
background image

Pub. 42004-454A

Model 352-001, 352-002, 352-003, and 352-004 Division 1 Telephones

Page: 3 of 13

f:\standard ioms - current release\42004 instr. manuals\42004-454a.doc
12/11

Mounting

N

OTE

: The mounting surface must be able to support the 28-lbs. weight of the telephone.

The enclosure must be securely fastened with 3/8-inch diameter steel mounting bolts located on all four
mounting feet. Stainless steel hardware is recommended in outdoor applications. Refer to Figure 2. The
suggested mounting height is 48 inches to the bottom of the enclosure.

N

OTE

: Refer to the Killark Installation, Operation, and Maintenance Data Sheet enclosed with the unit

for additional enclosure information.

Figure 2. Model 352 Series Division 1 Telephone Enclosure Mounting Details

Cable Entries

Refer to Figure 3 for the NPT conduit entries. Ensure any unused openings are sealed with proper fittings
per local standards. Use field wiring suitable for the ambient temperature. Any conduit NPT plugs
(blanking elements) must be explosion-proof with a Type 4X rating.

Figure 3. Model 352 Series Conduit Entries

Advertising