Installation, Mounting, Data connection – GAI-Tronics 12576-500 Deskset Panel Docking Station with VFD User Manual

Page 4: Power

Advertising
background image

Pub. 42004-691L2B

Model 12576-500 Desk Set Access Panel Docking Station with VFD

Page 4 of 7

f:\standard ioms - current release\42004 instr. manuals\42004-691l2b.doc
02/13

Installation

WARNING

Please adhere to all warnings, safety, and operating instructions on the unit

and in the installation manual.

1. Disconnect power before servicing.

2. Avoid servicing the unit during electrical storms.

3. Do not touch uninsulated wires.

Mounting

Remove the docking station from its protective packing. Simply position the docking station on a sturdy
horizontal surface in a convenient location.

N

OTE

:

There are two #8-32 threaded inserts located on the bottom of the assembly that can be used to

anchor the assembly to a horizontal surface. The maximum screw penetration that is allowed from the
base of the docking station to the internal hardware is 0.375 inches (9.5 mm).

Data Connection

Connect the RJ-11 data cable from the RJ-45 jack on the rear of the docking station to the API connecting
block located in the ADVANCE control cabinet. If the 7-foot cable is not long enough, use a twisted-pair
cable terminated on one end with either a RJ-11 or RJ-45 plug. This connection is not polarity-sensitive
and may be wired in either orientation.
N

OTE

: A 7-foot RJ-11 data cable is included with the desk set assembly.

Power

Connect the 3-conductor ac power cord provided with the docking station as follows:

1. Plug one end of the power cord into the 3-prong power connector at the rear of the power supply.

2. Plug the 5-pin DIN connector of the power supply into the 5-pin DIN jack on the rear of the docking

station.

3. Connect one end of the DB-15 cable to the desk set and slide the other end through the center of the

docking station, so that it is visible at the rear of the docking station.

4. If an optional desk mic has been purchased, slide the XLR plug on the end of the desk mic cable

through the center of the docking station and connect it to the desk set.

5. Set the desk set feet into the holes in the docking station allowing the desk set to lock into position.

6. Connect the other end of the DB-15 cable to the rear of the docking station.

7. Plug the power supply power cord into a grounded ac electrical outlet.

8. The assembly does not contain an integral power switch. The desk set access panel and docking

station will power up immediately.

Advertising