Options

 Single party line operation
 Speaker amplifier only (no handset)
 Alternate page destination
 Emergency party line (EPL)
 Auxiliary jack for headset operation
 Hazardous area approvals
 PVC or Hytrel handset cords in 6-, 15-, or 25-foot lengths
 Conformal coating for PCBA
 24 V dc power
 Volume Level Control (VLC) technology for alternate page volume
 SmartSeries technology featuring Ambient Level Sensing (ALS) and available remote monitoring
 Remote Terminal Unit (RTU) operation
 70V/100V speaker output
 All Call

Installation

Important Safety Instructions

This equipment is suitable for use in Zone 2/22 hazardous areas OR non-hazardous locations only.
Combinations of equipment in your system are subject to investigation by the local Authority Having
Jurisdiction at the time of installation.
Read, follow, and retain instructions – All safety and operating instructions should be read and followed
before operating the unit. Retain instructions for future reference.
Heed warnings – Adhere to all warnings on the unit and in the operating instructions.
Attachments – Attachments not recommended by the product manufacturer should not be used, as they
may cause hazards. Maximum system cable length is not to exceed two miles.
Servicing – Do not attempt to service this unit by yourself. Opening or removing covers may expose you
to dangerous voltage or other hazards. Refer all servicing to qualified service personnel.
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – Model 10401-201 Headset
and 10416-103 Extension Cord should be used in Group IIB or Group IIA areas only.

Capacitance values of 140 pF to 580 pF were measured on the external metallic unearthed components of
this equipment. As such, special care must be taken in installation location and environment to address
this hazard. See EN TR50404, “Electrostatics – Code of practice for avoidance of hazards due to static
electricity” for additional information in regards to proper installation and potential hazards.

WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed
or the area is known to be non-hazardous. Avertissement – Risque d’explosion – Avant de débrancher
l'équipement, couper le courant ou assurer que le secteur est su pour n’être pas hasardeux.

WARNING

In 24 V dc systems: Under NO condition should this equipment be operated

from a battery charger without the batteries connected.

In 24 V dc systems, most chargers have an unloaded output of 35 to 45 volts that can quickly damage the
equipment designed for nominal 24 volts. The maximum battery voltage should never exceed the