Performance specifications – GAI-Tronics IDR1000A DC Remote User and Installation Manual User Manual
Page 8
Foreword
IDR1000A DC Remote Desk Set User and Installation Manual
02/12 4
Performance Specifications
Color ..................................................................................................................................................... Black
Physical size .................................................................................................... 7.6 W
8.9 L 4.7 H inches
Weight ................................................................................................................................................ 2.4 lbs.
Temperature range .............................................................................................................. −35º C to +70º C
Humidity ...................................................................................................... 95% at 50º C (non-condensing)
Line impedance ................................................................................................................ 600 ohms nominal
Power input .................................................................................................. 10.5–16 V dc; 1.0 A maximum
Nominal input level ........................................................................................................................ −10 dBm
Nominal output level ...................................................................................... Range –25 to 0 dBm, −10 dB
Range –15 to +5 dBm into 560 ohms
Frequency response............................................................................................ +/−3 dB from 300–3000 Hz
Hum and noise .................................................................................. Less than −45 dB below rated outputs
Audio output to speakers ................................................. 1 watt minimum with level in compression range
Audio distortion .............................................................................................................. Less than 3% THD
Maximum number of remotes .................................................................................................................. Ten
DC current defaults
F1
................................................................................................................................................. 5.5 mA
F2
............................................................................................................................................... 12.5 mA
F3
............................................................................................................................................... −5.5 mA
F4
............................................................................................................................................. −12.5 mA
Monitor
(Programmable) ........................................................................................................... −2.5 mA
N
OTE
: Each button listed above can be programmed from −14 to +14 mA in 0.5 mA increments.
Safety ................................................................................................................... Class III SELV equipment
Powered by UL-listed (E104603) and CSA certified (LR67888) ac adapter
Line Interface ................................................................................................................ FCC Part 68 Exempt
(Category II Tariff #260 service for private/leased lie application)