GAI-Tronics 12562-105 Auxiliary Powered Emergency Telephone PCBA Replacement Kit User Manual

Page 3

Advertising
background image

Pub. 42003-212A

M

ODEL

12562-105

E

MERGENCY

T

ELEPHONE

PCBA

R

EPLACEMENT

K

IT

Page:

3 of 4

\\s_eng\gtcproddocs\standard ioms - current release\42003 kit manuals\42003-212a.doc
05/05

Models 297-101 and 298-101

Removing the Old PCBA

CAUTION

Disconnect the phone line.

1. Use the Model 233-001 Tamper-Resistant Screwdriver to loosen the six front panel screws.

2. Disconnect the microphone, speaker, switches, LED indicator, and keypad cables

(Model 298-101 only) from the PCBA. Record the location of each connection for later reconnection.

3. Disconnect the red and green wires from the telephone line connection on the PCBA. Save the modular

cord.

4. Unscrew the four screws securing the PCBA. Save the screws, and discard the PCBA.

Figure 2. Models 297-101 and 298-101 - Printed Circuit Board Detail

Advertising