Error codes – Hypertherm PHC Sensor User Manual

Page 49

Advertising
background image

Section 4: Troubleshooting

49

Section 4: Troubleshooting

Error Codes

Figure 21: Error Indications


The red ERROR LED indicates abnormal conditions. The error code is displayed in the PHC 3 digit LED
display as E.XX where XX represents the error number. The meanings are listed below. Most errors are
cleared by either removing the abnormal condition or with the application of the next “Cycle Start” from the
CNC.

E.01 CYCLE_START at power up Error

Reason:
The CNC CYCLE_START input was active when the PHC was powered up.
Solution:
Deactivate the CYCLE_START input on the CNC interface to clear the error.

E.02 Plate Contact at Home Error

Reason:
Ohmic contact sensed the work piece when the torch was at the maximum retract position.
Possible causes:
• A short circuit in either the nozzle connection wire or the torch consumables.

Red error
LED

Error code
Displays here

Advertising