Numeric pager display – DMP Electronics XR6 User Manual

Page 26

Advertising
background image

22

Account Number

Security Command Numeric Paging

Numeric Pager Display

This number has been programmed into your Security Command system
as an identifier. Whenever the system sends a message to your pager, it
will always send the account number first to identify itself.

Message ID

This is always a single digit, 1 to 6, that describes the message sent.

1 = Zone Alarm

3 = Area(s) Arming

2 = Zone Trouble

4 = Area(s) Disarming

6 = User Checkin

Zone, Area, or User Number

If this message is for a zone, the 1 to 2 digit zone number is displayed.

If this message is for areas that are being armed or disarmed, the area
numbers are shown in sequential order. Example: 1 2 4.

00128–301 234

Account

Number

Message

I D

Always

Zero

Zone, Area, or

User Number