INSTALLATION
MANUAL

INSTALLATION OF RRH END OF ASSEMBLY
Step 1

Mount the cable spool onto suitable de-reeling equipment.

Start unwinding side where the braided tube is attached (picture to

the right). Do not pull side where pulling tube is attached. Make

sure, that the spool can turn freely when unspooling.

Step 2

Remove the MLUH connector head from the mounting bracket by

unscrewing the two fixing screws.

Screws are retained by integral retaining washers.

Step 3

Secure the mounting bracket with hoseclamps (when fitting to a

pole/mast) or srews (when lifting to a wall).

Various mounting slots provided for different pole diameters.

Comment: take length of break-out and jumpers in consideration

when the bracket is positioned on the mast.

HUBER+SUHNER AG