HuddleCamHD 10x 720 User Manual

Page 8

Advertising
background image


Ver 1.1 1/30/15

code can control the dome camera.

SW2: Used for communication settings.

SW2 DIP-1,2,3: Baud Rate, Communication Protocol


SW2 DIP-4,5: IR Remote Control Receiving Address Table

IR Remote Address

SW2 Switch State (4-5)

DIP-4

DIP-5

0

OFF (Def)

OFF (Def)

1

OFF

ON

2

ON

OFF

3

ON

ON

SW2 DIP-6: IR Output

IR Out

SW2 DIP-6

Disabled

OFF (Def)

Enabled

ON


Baud Rate SW2 DIP-1 Communication

Mode

SW2 DIP-2 Communication

Protocol

SW2 DIP-3

9600bps

OFF (Def)

RS-232

OFF (Def)

VISCA

OFF (Def)

38400bps

ON

RS-485

ON

PELCO-D

ON