INSTALLATIONS

MB967-FT User’s Manual

23

LED1: Power & Status LED






STATUS LED GPIO33

GPIO32

YELLOW

H

L

RED

L

H

Index port: 4E
Data port: 4F
Device: 06
30h  bit1 = 1
C0h  set bit2, bit3 = 1 for GPO
C3h  set bit2, bit3 = 1 for Push Pull
C1h  bit2, bit3 (Control pin) for GPO32, 33















Signal Name

Pin #

Pin #

Signal Name

SIO GPIO32

C1

A1

SIO GPIO33

Reserved

C2

A2

Reserved

POWER LED-

C3

A3

POWER LED+

Status (Yellow / Red)

Reserved

Power (Green)

C1

C2

C3

A1

A2

A3