7.5 Configuration examples
For the examples:
Address JN2301 (ECU): 0x19, priority: 1

TxPGN0 default group extension (GS): 0x00
X: Angle value longitudinal X
Y: Angle value lateral Y

CAN identifier

8-byte data frame

0x4FF0019

LSB (X)

MSB

(X)

LSB (Y)

MSB

(Y)

-

-

-

-

TxPGN1 default group extension (GS): 0x01
X: Angle value longitudinal X
Y: Angle value lateral Y

CAN identifier

8-byte data frame

0x4FF0119

LSB (X)

��

��

MSB

(X)

LSB (Y)

��

��

MSB (Y)

8 Parameter mapping

8.1 Communication profile proprietary (0x500 – 0x1103)

Index

Type

Value

Unit

R/W

Reset

0x500

ASCII

Device name

R

0x501

ASCII

Software version

R

0x4003

UNSIGNED32

Serial number

R

0x1000

UNSIGNED8

Transmit parameter groups

number 0 active�
TxPGN0
2-byte angle longitudinal X
2-byte angle longitudinal X

0: is not sent cyclically
1: is sent cyclically

R/W

0x1001

UNSIGNED8

1 byte TxPGN0 LSB

PGN0: 0xFFXX

default: 0xFF00

R/W

X