Electrical connection – ilve KHVI60TC User Manual

Page 11

Advertising
background image

11

ELECTRICAL CONNECTION

The installation of this appliance and the connection to the electrical network should be
entrusted only to an electrician perfectly to the fact of the normative regulations and which
respects them scrupulously.
Protection against the parts under tension must be ensured after the builting-in.
The data of connection necessary are on the stickers place on the hob casing near the
connection box.
The connection to the main must be made using an earthed plug or via an omnipolar circuit
breaking device with a contact opening of at least 3 mm.
The electrical circuit must be separated from the network by adapted devices, for example :
circuit breakers, fuses or contactors.
Mains

Connection

Cable diameter Cable

Protection calibre

230V~1P 50Hz 1 Phase + N

3 x 2.5 mm²

H 05 RR 25 A *

400V~2P 50Hz 2 Phases + N

4 x 1.5 mm²

H 05 RR 16 A *

( * ) calculated with the simultaneous factor following standard 60335-2-6

Caution

!

Connect always the earth wire.
Respect the connection diagram placed near the connection box.
The connection box is located underneath at the back of the hob casing. To open the cover
use a medium screwdriver.

Connection of the hob

The ceramic hob can be connected in different ways:

Monophase 230V~1P+N

Biphase 400V~2P+N

Setting up the configurations:
For the various kinds of connection, use the brass bridges which are in the box next the
terminal.
Monophase 230V~1P+N
Put the bridge between terminal 1 and 2 (Phase).
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L to one of the
terminals 1 or 2.
Biphase 400V~2P+N
Attach the earth to the terminal “earth”, the neutral N to terminal 4, the Phase L1 to the
terminals 1 and the Phase L2 to the terminal 2.

Caution ! ensure that you :

- correctly attach the wires and the bridges.
- tighten the screws properly.

Before making the connection, we strongly advise you to locate the phase(s), neutral and
earth on the mains. If you have any doubts, call your electrician.

We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has been
equipped with a faulty earth connection.

Advertising